Tape a 12 inch by 12 inch piece of plastic wrap onto a part of the basement wall.
Acceptable moisture content in concrete walls.
The moisture content is indicated on the grade stamp.
Moisture meters can only check the moisture near the surface of a concrete slab which is not sufficient for predicting how the slab will react to having sealant applied or other building materials installed over it.
Acceptable moisture levels in concrete according to astm standard when testing via astm f2170 the rh level of a concrete slab needs to be at or below 75 unless the flooring system manufacturer provides alternate guidelines.
Check the plastic for the next several days noting when moisture.
I expect the same level would be acceptable on walls.
Moisture content is related directly to particular substrates or materials.
Generally speaking for drywall a safe moisture content mc would be less than 1 mc.
Anything above 1 mc in drywall would indicate a level of moisture that could compromise the integrity of the gypsum board.
From rodney white of independent consultant on march 4 2015.
This versatile option can be used to read.
In 2016 the society for protective coatings sspc expects to publish a new guidance document field methods for the determination of moisture in concrete and masonry walls and ceilings that will describe the types of instruments used for determining moisture content of walls prior to painting including recommended test frequencies.
Perhaps the most useful type of moisture meters an all in one meter uses both pin and pinless technology to measure moisture levels.
Seal the edges of the plastic wrap with tape.
Interior moisture sources such as humidifiers unvented clothes dryers bathrooms and cooking as well as the moisture in concrete after construction.
Concrete slabs often have thicknesses measured in feet not inches.
How moisture gets into concrete.
Moisture is transferred from the outside of the building to the basement interior by four mechanisms.
Painting a bathroom or painting a kitchen requires extra attention to detail because of the amount of moisture content the walls are likely to have.
Most concrete moisture meters only check surface moisture.
Exterior humid air that enters the basement and condenses on cooler surfaces.
Microbial growth is limited when the mc of gypsum board is below 0 6 when brick is below 0 8 when wallpaper is below 10 5 and when concrete is below 5.
Exterior walls may use a variety of materials from wooden siding to vinyl aluminum brick and stone.
Concrete slabs and floors can be excellent subfloor surfaces for tile and other floor coverings but too much moisture in the concrete can cause problems with flooring installations.